-40%

Split core Ground Resistnace Detector Ground Earth Resistance Tester 0.01 -100Ω

$ 128.3

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Ground Resistance Range: 0.010Ω~100Ω
  • Condition: New
  • Restocking Fee: No
  • Protection Level: IP54
  • Grounding Lead Interference Current: Should be avoid
  • Ground Resistance Resolution: 0.001Ω
  • Overflow Indication: test data>100Ω
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • CT Size: 56mm X 26mm
  • Current Range: /
  • Refund will be given as: Money back or replacement (buyer's choice)
  • CT structure: Closed loop
  • Country/Region of Manufacture: China
  • MPN: e45667
  • Weight: 1KG
  • Brand: VTSYIQI

    Description

    Split core Ground Resistnace Detector Ground Earth Resistance Tester 0.01 -100Ω
    Instruction:
    ETCR2800KB Split-core Ground Resistnace Detector, specialize for online monitoring grounding down lead connection status, circuit grounding resistance and metal circuit connection resistance. Range

    0.010Ω~100Ω. On-line testing, non-contact measurement, grounding wire pass through the perforation of the detector, definitely not influence grounding for lightening effect and normal operation, real time on-line testing. Use by RS485 wire communication or GPRS wireless communication data transmission, realize remote online monitoring .Detector built-in sensor and circuit board, completely sealed, ensure high-accuracy, high stability and high reliability of long time on-line monitoring at  field and indoors.
    Product Main Function
    1. On - line monitoring the earth resistance of grounding system
    2. Measure Range: 0.010Ω~100Ω
    3. No need to disconnect the grounding down lead and no need with auxiliary electrodes
    4. Rain and dust proof, can be installed and used in outdoor
    5. Network system can be built to realize real-time detection and remote monitoring
    6. EX-Mark: Exia

    BT3Ga
    7.Explosion Proof Certification: CE18.2332X
    Specification:
    Function
    Return circuit grounding resistance on-line monitoring, metal return circuit resistance connection online monitoring, grounding condition monitoring.
    CT structure
    Closed loop
    Power Supply
    Detector

    6VDC

    12VDC

    50mA Max(GPRS 12VDC 150mA Max). (Ui

    6V

    Ii

    50mA

    Ci:0μF

    Li:0mH

    Pi

    0.1W)

    User supply)

    Instrument and safety barrier matching relation

    Uo≤Ui

    Io≤Ii

    Po≤Pi

    Co≥Ci

    Lo≥Li
    Resistance Range
    0.01Ω~100Ω
    Resolution
    0.001Ω
    Accuracy
    ±2%rdg±3dgt(20

    ±5
    ℃,
    below 70%RH)
    CT Size
    56mm X 26mm
    Overflow Indication
    test data>100Ω, system software or LCD display “OLΩ” symbol;
    Connection line
    1pcs ,1 meter cord(5 core wire)
    Connection Identifier
    Red/brown---power supply input anode;
    Black--- power supply input cathode;
    Blue---RS485 signal anode;
    Grey---RS485 signal cathode;
    White--- grounding wire shield
    (power supply input cathode can connects with analog grounding by short circuit connection)
    Communication Method
    Wired network: RS485 communication protocol(support MODBUS)
    Wireless network: RS485 or GPRS communication protocol(support MODBUS)
    Network Points
    Wired network: 1 ~ 250 grounding points, scalable
    Wireless network: 60000 grounding points, can be expanded
    Communication distance
    Wired network: about 1500m,scalable
    Wireless network: not limited
    Alarm Indication
    the detector sound-light alarm
    Alarm Setting
    System Software Settings
    Data Display
    None
    Dimensions
    Detector: 124mm × 118mm × 76mm
    Weight
    Detector: 1KG
    Working  Temperature And Humidity
    -20

    ~55

    ;20%RH~90%RH
    Humidors Error
    Within 5%
    S hift
    Automatic shift
    Grounding Lead Interference Current
    Should be avoid
    External Magnetic Field
    <40A/m
    External Electric Field
    <1V/m
    Single Measurement time
    About 0.5 second
    Working current
    Detector: 50mA Max.(GPRS: 12VDC 150mA Max)
    Explosion-proof mark
    Ex ia

    B T3 Ga
    Explosion-proof Certification
    CE18.2332X.
    Protection Level
    IP54
    Power Supply Mode
    External power supply (Equipped by user)
    Packing :
    Package
    Outer package
    Carton
    Inner package
    None
    Accessory
    Meter
    1 pcs
    Power and Communication Cable
    1 pcs
    Manual
    1 pcs
    Certificate
    1 pcs
    Warranty Card
    1 pcs