-40%
Fluke 1630-2FC Earth Ground Clamp Meter
$ 1069.19
- Description
- Size Guide
Description
Untitled DocumentFluke 1630-2FC Earth Ground Clamp Meter
Model:
1630-2 FC
| Order No:
1630-2FC
Features a rugged design, this clamp meter is ideal for testing the grounding components of equipment in hard-to-reach areas, and areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Additionally, it identifies ground loop resistance without disconnecting and reconnecting the earth electrode.
Brand:
Fluke
Model:
1630-2 FC
Order No:
1630-2FC
Condition:
NEW
Description
Fluke 1630-2FC Earth Ground Clamp Meter
Stakeless earth ground loop and AC leakage current clamp for fast, safe indoor/outdoor earth ground resistance and AC leakage current tests
For use to test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not allow driving auxiliary test stakes. Remain on line - this earth ground clam meter identifies ground loop resistance without having to disconnect then reconnect the earth electrode from the system.
Additionally, this clamp meter is a rugged tool that comes equipped with a heavy-duty clamp jaw which stays in alignment and calibration even in every day, on-the-job industrial environments.
Features
AC leakage current measurement - identify ac leakage currents without disconnecting the earth ground stake from the grounding system - ideal for system troubleshooting
Rugged - heavy-duty clamp jaw stays in alignment and in calibration even in every day, on the job industrial environments
Logging measurements - the earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval
Alarm threshold - user-defined high/low alarm limits, for rapid measurement evaluation
Band-pass filter - selectable band-pass filter function removes unwanted noise from the ac leakage current measurement
Fluke Connect compatible
Stakeless measurements
Measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in previously difficult places: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.
With this test method, a two-process measurement is made around the earth ground wire or bus bar using the specially-designed jaw of this clamp. Auxiliary test stakes are not used at all. A known voltage is induced by the source in the clamp, and the current is measured by the sensor in the clamp. The tester automatically determines the earth loop resistance for this section of the earthing system.
Html->link('Fluke Clamp Selection Guide', DS . $filePathSetting, array('class' => 'btn btn-info', 'target' => "_blank", 'style' => '', 'escape' => false)); ?>
Included
Clamp Meter
Carrying Case
4 x AA Batteries
Safety Information Guide
Quick Reference Guide
Specifications
Electrical Specifications
Maximum Voltage to Earth Ground
1000 V
Frequency Range
40 Hz to 1 kHz
Overload Indication
OL
Data Logging Capacity
Minimum of 32,760 measurements
Data Logging Interval
1 second to 59 minutes and 59 seconds
Display Reading Specification with Standard Loop Resistance
Input (&ohm)
0.474
0.5
10
100
Minimum
0.417
0.443
9.55
96
Maximum
0.531
0.558
10.45
104
Safety
General
IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1
Measurement
IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current Clamp for Leakage Current Measurements
IEC/EN 61557-13: Class 2, ≤30 A/m
Resistance to Earth
IEC/EN 61557-5
Effectiveness of the Protective Measures
IEC/EN 61557-16
Electromagnetic Compatibility (EMC)
International: IEC/EN 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
Korea (KCC): Class A equipment (Industrial broadcast and communications equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Wireless Radio
Frequency Range
2412 to 2462 MHz
Output Power
<10 mW
Radio Frequency Certification
FCC ID:T68-FBLE IC:6627A-FBLE
General Specifications
Battery
Type: 4 x AA Alkaline batteries (IEC/EN LR6)
Life: More than 15 hours
Ingress Protection
IEC/EN 60529: IP30 with jaw closed
LCD
Digital reading: 9999 counts
Refresh rate: 4 per second
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
4 to 140°F (-20 to 60°C)
Operating Humidity
Non condensing (<50°F) (<10 °C)
≤90% RH (at 50 to 86°F [10 to 30°C])
≤75% RH (at 86 to 104°F [30 to 40°C])
≤45% RH (at 104 to 122°F [40 to 50°C])
Reference Temperature
73 ±9°F (23 ±5°C)
Temperature Coefficient
0.15% x (specified accuracy)/°C (<64.4 or >82.4°F [<18 or >28°C])
Operating Altitude
6561' (2000 m)
Storage Altitude
39,370' (12,000 m)
Dimensions
11.1 x 4.1 x 1.9" (283 x 105 x 48 mm)
Weight
1.94 lbs (880 g)
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.